| Principle of cleaning PL-Blower |
Function in detail
- The lance tube with two opposite high-performance nozzles is oscillated and moved into the flue gas pass.
- The blowing process begins as soon as the two nozzles have passed through the boiler wall.
- During the blowing process the lance tube continues to oscillate and move into the flue gas pass.
- On reaching the front-side end position the direction of movement changes and the lance tube returns to its starting position.
|
 |
|
| Principle of cleaning PB-Blower |
Function in detail
- The blowing tube is equipped with high-performance nozzles over the whole length and is movably supported in the flue gas pass.
- During the blowing process the blowing tube continues to oscillate and move into the flue gas pass.
- On reaching the front-side end position the direction of movement changes and the blowing tube returns to its starting position.
|
 |
|